Item / Model | JSA-AIPTU410-94B | JSA-AIPTU410-94P | JSA-AIPTU410-94D |
Version Classification | Standard Version | Professional Version | Developer Version |
P T U P a r a m s | Max. Load | ≤10kg |
Load Type | Top Load |
Transmission Type | Worm Gear Transmission / Design of Horizontal Hoisting Structure |
Pan Range | 0°~360° Continuous Rotation |
Tilt Range | -90°~40° |
Pan Speed | 0.01°~100°/S |
Tilt Speed | 0.01°~40°/S |
Repeatability | ±0.1° |
Preset Position | ≤200 |
Communication Protocol | Pelco D |
Baud Rate | 9600 |
Address Code | 1 |
Data Feedback | Supports angle/azimuth data query or real-time feedback (selectable) |
Top Cable Outlet | DC24V*1/1A, DC12V*1/1A; Slip ring straight-through cable: RJ45/100Mb*1 |
Bottom Cable Inlet | DC24V*1/5A, RS422*1, RJ45/100M (PTU Control)*1, GND*1, Slip ring straight-through cable: RJ45/100Mb*1 |
M a n a g e m e n t M o d u l e | RAM | 1G | 2G | 4G |
Storage Space | 8G | 16G | 32G |
Operating System | Linux |
System Architecture | Browser/Server (B/S) Mode |
Network Protocol | DHCP, HTTP, HTTPS, DNS, NTP, TCP, IGMP |
PTU Protocol | PELCO_D, AIPTZ |
PC Client | Supported | Supported | Supported |
Mobile Client | Not Supported | Supported | Supported |
API Interface | Not Supported | Not Supported | API documentation and code samples provided |
Concurrent Connections | ≤10 | ≤50 | ≤100 |
Log Storage | ≤5000 entries | ≤20000 entries | ≤100000 entries |
W E B P T U C o n t r o l | Device Status | Device Baud Rate / Address Code, Online Status, Current User, Current Position |
Basic Operation | Up/Down, Left/Right, Up-Left/Down-Left, Up-Right/Down-Right, Stop |
Angle Control | Input specified absolute angle for Pan or Tilt, then execute manually |
Query Feedback | Send Pan or Tilt angle query command, reply displays and outputs current value |
Real-time Feedback | Feedback and display current Pan and Tilt angle values at specified frequency |
Speed Setting | Set the Pan or Tilt speed level via progress bar |
Preset Position | Set, delete, and call preset position operations |
A/B Line Scan | Set horizontal Point A and Point B to achieve linear scanning between two points |
Horizontal Ring Scan | Supports horizontal continuous rotation scanning; scanning speed is configurable |
Auto Cruise | Supports programming ≤8 cruise groups, each group supports ≤16 presets, and dwell time at each preset is independently configurable |
Guard Task | Can set and execute guard scheduled tasks, supporting guard presets, line scan, horizontal rotation, and cruise groups |
Power-off Memory | Supports memory of position 10 seconds before power-off, automatically returns to that position after power-on recovery |
Zero Position Setting | Supports setting current position as horizontal or vertical zero position (Admin only) |
Restart | Supports one-click restart of the device (Admin only) |
Restore Settings | Clear current settings and restore factory default configuration (Admin only) |
Command Display | The command status area displays commands running in the system in real time, helping developers quickly learn commands and improve integration efficiency. |
Authority Management | Distinguishes between admin group and operator group members; operation permissions for different user groups can be set for different functional modules |
System Log | Records login and operation logs, can query corresponding logs by date and time |
O t h e r P a r a m s | Power Supply | DC24V/5A; ≤100W |
Operating Temperature | -35°C~65°C |
Operating Humidity | <90%RH |
Protection Rating | IP66 |
Weight | ≈10kg |
Dimensions | 212*200*345mm [L*W*H] |